ESXi 로그 레벨 낮추는 것보다
rsyslog 구성해서 rsyslog 필터링 걸어주는게 낫다.
Tuning ESXi (6.0) logging
Rhttpproxy flood with verbose messages
Login to ESX via SSH (enable that if needed).
[root@esx1:~] cd /etc/init.d
[root@esx1:/etc/init.d] ls
DCUI epd nfsgssd sensord usbarbitrator vsanObserver
ESXShell hostd nscd sfcbd vmfstraced vsandevicemonitord
SSH iofiltervpd ntpd sfcbd-watchdog vmsyslogd vsantraced
cdp lacp osfsd slpd vmtoolsd vsanvpd
clomd lbtd pcscd smartd vmware-fdm vvold
cmmdsd lwsmd rabbitmqproxy snmpd vobd wsman
dcbd memscrubd rhttpproxy storageRM vprobed xorg
ddecomd nfcd sdrsInjector swapobjd vpxa
[root@esx1:/etc/init.d]
As you see, rhttpproxy has it's own initscript. Looking into it, a config file /etc/vmware/rhttpproxy/config.xml discovered. Edit it and replace verbose level to error level as shown here:
..
<!-- default log level -->
<level>error</level>
..
Restart service by:
[root@esx1:/etc/init.d] ./rhttpproxy restart
watchdog-rhttpproxy: Terminating watchdog process with PID 34267
VMware HTTP reverse proxy stopped.
VMware HTTP reverse proxy started.
Repeat for other ESXes.
Hostd flood with warning messages
Although it is possible to fix staff in file (/etc/vmware/hostd/config.xml) exactly as we did for rhttpproxy and restart service by ./hostd restart, these parameters are avaliable via Advanced System Settings in vSphere Web Cient.
Open client, select ESX, go to Manage tab, then Settings and finally Advanced System Settings. Enter hostagent in search field, wait for results. You should select Config.HostAgent.log.level property and edit it (click on pen icon) In pop-up window switch level to error.
Repeat for other ESXes.
The following message not directly related to HostAgent, it forwards form some facility, named LikewiseGetDomainJoinInfo. Still not found the source of problem.
Hostd: [LikewiseGetDomainJoinInfo:355] QueryInformation(): ERROR_FILE_NOT_FOUND (2/0):
hostd-probe flood with verbose messages
hostd-probe woken up by crond, therefore no restart needed after fixing configuration file /etc/vmware/hostd/probe-config.xml
Replace default log level to error.
Fault Domain Manager (FDM) verbose messages
After upgrading to ESX 6.5, a new flood comes from FDM. The treatment is similar. Examine /etc/init.d/vmware-fdm to discover /etc/opt/vmware/fdm/fdm.cfg configuration file. Replace "verbose" log level to other value (I've changed to "warning") and restart service:
[root@esx1:~] /etc/init.d/vmware-fdm restart
Stopping vmware-fdm:Setting the memory limit for fdm resource pool on this host to
0 MB
success
Starting vmware-fdm:Setting the memory limit for fdm resource pool on this host to
200 MB
success